Primax Australia

Pump Bearings have Short Life


Obstruction in pump casing / impeller

Impeller out of balance

Shaft bent

Shaft running of centre because of worn bearings or misalignment

Misalignment

Bearings worn

Excessive thrust caused by mechanical failure inside pump

Lack of bearing lubrication

Incorrect assembly of stacked bearings, i.e. angular contact ball bearings fitted front-to-front instead of back-to-back

Dirt in bearings

Rusting of bearings from water in housing

 
 
 